Performance Tests
 
 
Supported Tests
Torque, speed, current, voltage, input power, output power, time, efficiency, direction of rotation
Additional Tests
Speed and torque spectrum, speed and torque oscillations, friction torque, friction spectrum, cogging torque level, and back EMF.
System Accuracy
± 0.2%
 
Torque Range
Not limited
 
Sensors
Industry standard. Accuracy: ± 0.3°.
 
 
 
 
Power Analyzer
Electronic Input
 
 
Voltage
110-230 V ± 10%
 
Frequency
50/60 Hz
 
Motor Input
 
 
Voltage Range
See table below.
 
Current Range
See table below.
 
Frequency
47-63 Hz
 
Accuracy
± 0.2%
 
 
 
 
Power Analyzer Name
Model
Current (*)
A
Voltage
V
PAS 10 - 30/60/200
4010
0.06-10
3-30/ 10-60/ 10-200
PAS 25 - 30/60/200
4025
0.08-25
3-30/ 10-60/ 10-200
PAS 50 - 30/60/200
4050
0.2-50
3-30/ 10-60/ 10-200
PAS 100 - 30/60/200
4100
3-100
3-30/ 10-60/ 10-200
PAS 200 - 30/60/200
4200
6-200
3-30/ 10-60/ 10-200
PAS 400 - 30/60/200
4400
12-400
3-30/ 10-60/ 10-200
 
 
 
 
 
PA 600 - 30/60/200
4600
18-600
3-30/ 10-60/ 10-200
PA 800 - 30/60/200
4800
24-800
3-30/ 10-60/ 10-200
PA 1200 - 30/60/200
41200
36-1200
3-30/ 10-60/ 10-200
 
 
 
 
(*) Current Range: the minimum is for no load current and the maximum is for starting current.
 
Please choose one or more Power Analyzers to cover you range of motors.
 
Mechanical Specifications
Dimensions
150 x 92 x 80 cm (W x H x D)
 
Weight
95 kg (approx.)
 
 
 
 
Motor Holding Device
Dimensions
20 x 46 x 30 cm (W x H x D)
 
Weight
7 kg
 
Customizations
Customized devices available, according to customer's requirements
 
 
 
 
Calibration
 
 
 