The anderon meter mainly consists of three components: the indication unit, the drive unit, and the converter.
|
Indication Unit ADA-15 |
The ADA-15 Indication Unit is a readout for the anderon value. |
|
Measuring band |
L: 50-300 Hz M: 300-1800 Hz H: 1800-10000 Hz |
|
Range |
1/10/100 Anderon |
|
Display |
Digital 3.3 digits |
|
Power supply |
AC 90-110 V, 50/60 Hz, 20 VA |
|
Dimension |
430 (W) * 168(H) * 427 (D) mm |
|
Weight |
16 kg |
|
|
||
Converter ADS-12 |
The ADS-12 Converter is a velocity sensor that converts mechanical vibration into electrical signals |
|
Sensitivity |
3±0.2 mV/usp usp = 12.486mm/s (0.8 Grms at 100Hz) |
|
Frequency characteristics |
±1dB at 50-10000 Hz Resonance Frequency: No less than 20 kHz at 0.1 mm depth |
|
Coil resistance |
30Ω at 23±2ºC |
|
Probe force |
0.40 ±0.05 N at 0.1 mm depth 0.65 ±0.08 N at 0.2 mm depth 0.90 ±0.10 N at 0.3 mm depth |
|
Tip of probe |
Cemented carbide SR10 |
|
Dimensions |
70 ± 2 (W) * 46.1 ± 2 (H) * 19.7± 1 (D) mm |
|
Mass |
260 ± 25 g |
|
|
||
Drive Unit ADM-100 series |
The ADM-100 series Drive Unit is for rotating ball bearing of smaller sizes. |
|
|
Max. size of ball bearing |
Outer ring outside diameter: 50 mm |
|
Spindle speed |
1800 r/min±2%, 20ºC at no load |
|
Spindle drive system |
Direct drive |
|
Spindle-Arbor taper |
B & S #3 |
|
Lubrication |
Self circulation oil system |
|
Power supply |
AC 90-110 V, 50/60 Hz, 20VA |
|
Dimension |
300 (W) * 420 (H) * 474 (D) mm |
|
Mass |
80 kg |
Drive Unit ADM-500 series |
The ADM-500 series Drive Unit is for rotating ball bearing of medium sizes. |
|
|
Spindle speed |
1800 r/min±2%, 20ºC at no load |
|
Spindle drive system |
Direct drive |
|
Spindle-Arbor taper |
B & S #7 |
|
Lubrication |
Self circulation oil system |
|
Power supply |
AC 90-110 V, 50/60 Hz, 20VA |
|
Dimension |
700 (W) * 1252 (H) * 830 (D) mm |
|
Mass |
300 kg |