Performance Tests
|
|
|
Supported Tests
|
Torque, speed, current, voltage, input power, output power, power factor, time, efficiency, frequency, direction of rotation
|
Additional Tests
|
Speed and torque spectrum, speed and torque oscillations, friction torque, friction spectrum, cogging level
|
System Accuracy
|
± 0.2%
|
|
Torque Range
|
Not limited
|
|
Sensors
|
Industry standard. Accuracy: ± 0.3°.
Optional feature: testing compressor without connecting sensor to motor shaft
|
|
|
|
|
Power Analyzer
|
Electronic Input
|
|
|
Voltage
|
110-230 V ± 10%
|
|
Frequency
|
50/60 Hz
|
|
Motor Input
|
|
|
Voltage Range
|
30-280 V for 1PH
50-530/660/750 V for 3PH
|
|
Current Range
|
See table below.
|
|
Frequency
|
47-63 Hz
|
|
Accuracy
|
± 0.2%
|
|
|
|
|
Power Analyzers
|
Name
|
Model
|
Current (*)
A
|
Voltage
V
|
|
PAS 10-280
|
3601
|
0.06-10
|
24-280
|
|
PAS 25-280
|
3611
|
0.08-25
|
24-280
|
|
PAS 50-280
|
3621
|
0.2-50
|
24-280
|
|
PAS 90-280
|
3631
|
0.5-90
|
24-280
|
|
PAS 530-50-40K
|
5621
|
0.1-50
|
50-530
|
|
PAS 530-90-40K
|
5631
|
1-90
|
50-530
|
|
PAS 660-200-40K
|
5641
|
5-200
|
50-660
|
|
PAS 750-300-40K
|
5651
|
10-300
|
50-750
|
|
|
|
|
|
(*) Current Range: the minimum is for no load current and the maximum is for starting current.
Please choose one or more Power Analyzers to cover you range of motors.
|
|
Mechanical Specifications
|
Dimensions
|
74 x 92 x 74 cm (W x H x D)
|
|
Weight
|
70 kg (approx.)
|
|
|
|
|
Motor Holding Device
|
Dimensions
|
20 x 46 x 30 cm (W x H x D)
|
|
Weight
|
7 kg
|
|
Customizations
|
Customized devices available, according to customer's requirements
|
|
|
|
|
Calibration
|
|
|
|
Adjustments are made through calibration software interface. Calibration information is stored in the system database.
|
|