Performance Tests
 
 
Supported Tests
Torque, speed, current, voltage, input power, output power, power factor, time, efficiency, frequency, direction of rotation
Additional Tests
Speed and torque spectrum, speed and torque oscillations, friction torque, friction spectrum, cogging level
System Accuracy
± 0.2%
 
Torque Range
Not limited
 
Sensors
Industry standard. Accuracy: ± 0.3°.
Optional feature: testing compressor without connecting sensor to motor shaft
 
 
 
 
Power Analyzer
Electronic Input
 
 
Voltage
110-230 V ± 10%
 
Frequency
50/60 Hz
 
Motor Input
 
 
Voltage Range
30-280 V for 1PH
50-530/660/750 V for 3PH
 
Current Range
See table below.
 
Frequency
47-63 Hz
 
Accuracy
± 0.2%
 
 
 
 
Power Analyzers
Name
Model
Current (*)
A
Voltage
V
 
PAS   10-280
3601
0.06-10
24-280
 
PAS   25-280
3611
0.08-25
24-280
 
PAS   50-280
3621
0.2-50
24-280
 
PAS   90-280
3631
0.5-90
24-280
 
PAS   530-50-40K
5621
0.1-50
50-530
 
PAS   530-90-40K
5631
1-90
50-530
 
PAS   660-200-40K
5641
5-200
50-660
 
PAS   750-300-40K
5651
10-300
50-750
 
 
 
 
 
(*) Current Range: the minimum is for no load current and the maximum is for starting current.
 
Please choose one or more Power Analyzers to cover you range of motors.
 
Mechanical Specifications
Dimensions
74 x 92 x 74 cm (W x H x D)
 
Weight
70 kg (approx.)
 
 
 
 
Motor Holding Device
Dimensions
20 x 46 x 30 cm (W x H x D)
 
Weight
7 kg
 
Customizations
Customized devices available, according to customer's requirements
 
 
 
 
Calibration
 
 
 
Adjustments are made through calibration software interface. Calibration information is stored in the system database.